NICOR 4 Inch Line Voltage
Recessed Housings and Trims
Nicor Lighting offers a complete line of 4 " Line Voltage Housings and Trims. Trims can be as basic as an Open trim or Directional as a Gimbal Ring. There are Trims for use in showers and Decorative Trims in Designer Finishes.
ALL DIMENSIONS in INCHES
CLICK IMAGE for LARGER VIEW
4" NON-IC AIRTIGHT HOUSINGS (1)
19000A (1)
15000R (1)
A
8 1/2
B
14 1/4
C
10 1/4
D
5 1/2
E
4 1/8
A
11 3/8
B
4
C
5 1/2
D
4 3/4
Universal Airtight Non-IC Housing
Remodel Airtight Non-IC Housing
• Suitable for new construction in residential and commercial applications.
• NON-IC. Insulation must be kept a minimum of 3” from housing.
• 105° C rated integral thermal protector guards against improper lamping and misuse of insulation materials.
• Adjustable socket bracket assures proper and consistent lamp positioning.
• 5 1/2” height allows use in 2” x 6 ” joist construction.
• UL damp location listed, UL feed-through listed, CUL approved.
• Housing is secured to plaster frame with screws and can be removed for access to junction box.
• Housing adjusts from 1/2” to 1 1/2” to accommodate
ceiling thickness.
• Listed for through branch circuit wiring and includes
several 3/4” knockouts. Four pry-outs with integral
strain relief simplify Non-Metallic Building Wire installation.
• Supplied with three push-in wire connectors.
• Heavy-gauge NICOR captive hanger bars provide greater stability, allowing housing to be positioned at any point within a 24” joist span, then locked in place with set screws. Unique hanger bar lip design helps align can to joist. Four double-headed captive nails provide for ease of installation. Bars can be repositioned 90° on plaster frame without tools. Bars fit onto T-bar spine for quick alignment and can be permanently secured. Score lines allow bars to be shortened without tools to accommodate a 12” joist span.
• Listed for through branch circuit wiring and includes
several 3/4” knockouts.
• Supplied with three push-in wire connectors.
• Suitable for new construction in residential and commercial applications.
• IC Rated. Suitable for direct contact with Insullation.
• Airtight housing limits the exchange of air between ceiling plenum and heated/cooled areas.
• Washington State Energy Code approved to meet restricted airflow requirements.
• 105° C rated integral thermal protector guards against improper lamping and misuse of insulation materials.
• Adjustable socket bracket assures proper and consistent lamp positioning.
• 6” height allows use in 2” x 8” joist construction.
• UL listed for direct contact with insulation, UL damp location listed, UL feed-through listed, CUL approved.
• Housing is secured to plaster frame with screws and can be removed for access to junction box.
• Housing adjusts from 1/2” to 1 1/2” to accommodate
ceiling thickness.
• Listed for through branch circuit wiring and includes
several 3/4” knockouts. Four pry-outs with integral
strain relief simplify Non-Metallic Building Wire installation.
• Supplied with three push-in wire connectors.
• Heavy-gauge NICOR captive hanger bars provide greater stability, allowing housing to be positioned at any point within a 24” joist span, then locked in place with set screws. Unique hanger bar lip design helps align can to joist. Four double-headed captive nails provide for ease of installation. Bars can be repositioned 90° on plaster frame without tools. Bars fit onto T-bar spine for quick alignment and can be permanently secured. Score lines allow bars to be shortened without tools to accommodate a 12” joist span.